Brand new prefabricated data center solutions for server room air cooling projects HAIRF designed
Hot sale Haif Modular Data Center integrated solution with RACKS, UPS, PDU, Precision air conditoner
Product Features:
* High efficiency: efficient and energy saving;
* Modularity: modular UPS+Battery, extendibility;
* Intelligence, visibility: intelligent design of monitoring and management system;
* Isolation of internal & external module, anti-dust and dehumidification;
* Rapid deployment: no need engineering survey, plug and play, facilitates the operation with one
stope deployment;
* Environmental and energy management, Operation optimization, PUE maximum;
* Cloud computing: network connections management, parallel or multi-network;
* Precision cooling system, energy-saving: Precision cooling, central air condition needless, cost
reduction
* Standard cabinet: standard aluminium frame structure EIA-310-D, easy installation within 5
minutes
* All-in-one: Integrated of rack, air condition, UPS, PDU monitoring & on-site management system etc
Modularization cooling system in the container form including UPS, AIR CONDITIONER, BE PROTECTED ETC
Model | HMDC-0803 | HMDC-0805 | HMDC-0808 | HMDC-1603 | HMDC-1605 | HMDC-1608 | HMDC-2403 | HMDC-2405 | HMDC-2408 |
Cabinet subsystem | |||||||||
Dimension | W*D*H: 600*1100*2000, other size can be customized | ||||||||
QTY | 8units | 16units | 24units | ||||||
Cabinet power density | 3kw/rack | 5kw/rack | 8kw/rack | 3kw/rack | 5kw/rack | 8kw/rack | 3kw/rack | 5kw/rack | 8kw/rack |
Cabinet total power | 24kw | 40kw | 64kw | 48kw | 80kw | 128kw | 72kw | 120kw | 192kw |
Cabinet power supply | Dual PDU power supply | ||||||||
Distribution subsystem | |||||||||
Power supply | 2N power supply, Tier I grade | ||||||||
Column counter | Precision column cabinet : double loop power supply | ||||||||
UPS | Modular UPS | ||||||||
Model | X7-50 | X7-75 | X7-100 | X7-75 | X7-100 | X7-150 | X7-100 | X7-150 | X7-250 |
Capacity | 50KVA | 75KVA | 100KVA | 75KVA | 100KVA | 150KVA | 100KVA | 150KVA | 250KVA |
Configuration | 2 sets | ||||||||
Redundant architecture | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+1) | 2(N+2) |
Refrigeration subsystem | |||||||||
PAC | In-row air conditioner | ||||||||
Model | R261A | R401A | R261A | R161A | R261A | R261A | R261A | R261A | R401A |
Air supply | Horizonal air supply | ||||||||
Cooling method | Air cooled/ water cooled/ chilled water | ||||||||
Cooling capacity(kw) | 25.5 | 41.5 | 25.5 | 15.5 | 25.5 | 25.5 | 25.5 | 25.5 | 41.5 |
Configuration | 2pcs | 2pcs | 4pcs | 4pcs | 4pcs | 6pcs | 4pcs | 6pcs | 6pcs |
Redundant architecture | 1+1 redundancy | 1+1 redundancy | 3+1 redundancy | 3+1 redundancy | 3+1 redundancy | 5+1 redundancy | 3+1 redundancy | 5+1 redundancy | 5+1 redundancy |
Monitoring subsystem | |||||||||
Terminal interface | 21inch human touch screen | ||||||||
UPS monitoring | support | ||||||||
Battery online monitoring | Support(optional) | ||||||||
Power distribution monitoring | Support | ||||||||
PAC monitoring | Support | ||||||||
Leakage monitoring | Support | ||||||||
Temperature and huminity monitoring | Support | ||||||||
Smoke monitoring | Support: credit card/ password/ fingerprint(optional) | ||||||||
CCTV | Sopport | ||||||||
Access control | Support | ||||||||
System status | |||||||||
Size L*W | 5.1*3.4m | 5.4*3.4m | 5.4*3.4m | 7.8*3.4m | 7.8*3.4m | 8.1*3.4m | 10.2*3.4m | 10.5m*3.4m | 12*3.4m |
Area | 17.34m2 | 18.36m2 | 18.36m2 | 26.52m2 | 26.52m2 | 27.54m2 | 34.68m2 | 35.7m2 | 40.8m2 |